identiFINDER® R425 Next Generation Radionuclide Identification Device

Teledyne FLIR
The identiFINDER® R425 is the next generation of the most deployed radionuclide identification device (RID), offering 360-degree coverage so you can locate and measure gamma and neutron radioactive sources with confidence. The updated capabilities on the identiFINDER R425 include a higher resolution detector option, higher dose rate capability, and a new glass screen cover for scratch protection. With the familiar identiFINDER user interface and 3-button control, you can operate the R425 quickly, communicate results, and take command of any situation, in any environment, remotely. When other systems fail in extremely high gamma fields, the identiFINDER R425 provides pinpoint accuracy and remains fully operational. The R425 provides an ideal balance of size, weight, and performance for various missions including surveying, emergency response, and environmental monitoring.

Gamma and Gamma/Neutron Models

BETTER DETECTION IN ALL DIRECTIONS
New cubic detector design, sourceless stabilization, advanced heuristics, and hybrid identification techniques enable high performance detection in all directions; 3x more sensitive gamma and 2x more sensitive neutron detection.

POWER THROUGH YOUR MISSION
IP67-rated, ergonomic design is 15% lighter than previous generations, while the exceptional 12-hour battery life provides the right balance for a variety of missions.

SITUATIONAL AWARENESS AND SUPPORT WHEN YOU NEED IT
Remote data viewing, operation, and reach back is made possible through communication features including dual USB-C ports, Teledyne FLIR's trusted web interface, the Teledyne FLIR RAD Mobile Application, and a universal API that enables integration with user deployed networks.

The updated identiFINDER R425 features three key improvements on the original R425. We have added a higher resolution detector option, a higher dose rate capability, and improved ruggedness with a new, scratch resistant glass screen cover.

HIGHER RESOLUTION DETECTOR
The updated identiFINDER R425 offers a ruggedized LaBr detector option. This adds a higher resolution detector option which provides a better energy resolution capability.

HIGHER DOSE RATE CAPABILITY
The higher dose rate capability is enabled by increasing the GM tube up to 1000 rem/h. In situations where other systems can become inoperable, the energy compensated GM tube is utilized to keep the instrument fully operational in extremely high gamma fields, up to 1000 rem/h should you need it.

GLASS SCREEN COVER
We've increased the ruggedness of the updated identiFINDER R425 with a new, scratch-resistant glass screen cover. This will provide improved protection as well as screen visibility for the lifespan of the detector.